APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10635 Issued:2002-09-23
Revised:2012-04-01
Style 10635 Single conductor with extruded insulation

Rating90 deg C, 1000 Vac, 1200 Vdc, Horizontal flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor30 AWG - 1000 kcmil solid or stranded round, tinned or bare copper.
InsulationPVC, 30 mils min average, 27 mils minimum at any point.
CoveringOptional. Extruded nylon in 4-mil minimum thickness or lacquered braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances; or Internal Wiring of Appliances where exposed to oil at a temperature not exceeding (60 deg. C or 80 deg. C, whichever is applicable). Tags may also indicate the following: 3500 V peak - For electronic use only.

UL and the UL Logo are trademarks of UL LLC © 2024