APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1064 Issued:1959-05-01
Revised:2012-04-19
Style 1064 Single-conductor cable using non-integral jacket.

Rating60 deg C, 600 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG, stranded, consisting of 30 AWG strand.
InsulationExtruded PE, 1/32 inches nominal thickness.
ShieldOptional.
CoveringNon-extruded lacquered cotton, rayon or glass, over conductor shield.
JacketExtruded PVC, 1/32 inches nominal thickness, over the shielding.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph and Volume Control Use.