APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1065 Issued:1959-05-01
Revised:2011-07-21
Style 1065 Single Conductor with Extruded Insulation

Rating60 deg C, 600 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG stranded consisting of 30 AWG strands.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
ShieldOptional.
CoveringLacquered cotton, rayon or glass over conductor shield.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph and Volume Control Use.