Rating | 105 deg C, 1000 Vac, Horizontal flame, Oil resistant 60 deg C. |
|
Conductor | 28 AWG - 1000 kcmil solid or stranded round, tinned or bare copper. |
|
Insulation | TPE, Recognized Component (QMTT2) Polymeric Material for Use in Wire & Cable suitable for a minimum of 75 deg C water resistance. If proprietary water resistant TPE compound is used, see Facing Page for compound designation. |
| 28-12 AWG conductor size | 15 mils min average | 13 mils minimum at any point |
| 11-10 AWG | 20 avg | 18 min |
| 9-5 AWG | 30 avg | 27 min |
| 4-2 AWG | 39 avg | 35 min |
| 1-4/0 AWG | 47 avg | 42 min |
| 213-500 kcmil | 60 avg | 54 min |
| 501-1000 kcmil | 70 avg | 63 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For further processing into jacketed cables. Also suitable where exposed to oil at a temperature not exceeding 60 deg C. |
|