APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10654 Issued:2003-01-22
Revised:2012-04-17
Style 10654 Single conductor with extruded insulation and jacket

Rating200 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG, solid or stranded.
InsulationExtruded PTFE, 7 mils minimum average thickness, 6 mils minimum thickness at any point.
ShieldWire braid or wire wrap.
JacketExtruded PFA, 8 mils minimum average thickness, 7 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment where not subjected to mechanical abuse.