APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10657 Issued:2003-01-22
Revised:2011-10-28
Style 10657 Coaxial Cable.

Rating200 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded round.
InsulationFEP, 7 mils min average, 6 mils minimum at any point.
ShieldWire braid or wire wrap.
JacketPFA, 8 mils min average, 7 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment where not subjected to mechanical abuse.