APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10687 Issued:2003-05-28
Revised:2012-06-19
Style 10687 Single Conductor Cable using non-integral Jacket

Rating80 deg C, 600 Vac Horizontal flame.
Conductor32 AWG minimum. Solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
ShieldOptional.
CoveringOptional.
Jacket
Dia of Cable Under JacketMin Average Thickness MilsMin At Any Point Thickness Mils
0.700 or less3024
0.701 - 1.0004536
1.001 - 1.5006048
1.501 - 2.5008064
- Major dia if cable is flat or oval
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.