APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10717 Issued:2003-08-20
Revised:2012-04-01
Style 10717 Single conductor with extruded insulation

Rating105 deg C, 150 Vac, Horizontal flame.
ConductorInner Conductor - 24 AWG (4 conductor strands, 10.0 mil strand diameter, 0.5 inches lay of strands). Heater Conductor - 41 AWG - 34 AWG solid, tinned or bare copper.
InsulationInner Insulating Covering, Separation Sensor Layer - PVC or PE, 14 mils minimum average thickness, 13 mils minimum thickness at any point, 25 mils core diameter. Not evaluated as a Sensor Layer. Outer Insulation - PVC, 25 mils min average, 22 mils minimum at any point.
AssemblyThe core with inner conductor, inner insulation, heater conductor(70 -13 turns per inch), then outer insulation.
Misc.Core - Tinsel wire fibre core, 4 wires.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring, High Resistance Heater WireSee facing page for special features.