APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10731 Issued:2003-09-26
Revised:2017-11-21
Style 10731 Single Conductor with Extruded Non-Integral Jacket

Rating80 deg C, 600 Vac, Horizontal Flame.
Conductor36 AWG min., solid or stranded round, or flat.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyOne individually insulated conductor to form a round or flat cable.Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the individual conductor.
CoveringOptional.
ShieldOptional.
JacketTPU
diameter of core assembly under jacketminimum average thicknessminimum thickness at any point
o.350 inch or less15 mils12 mils
0.351-0.700 inch30 mils24 mils
0.701-1.000 inch40 mils36 mils
1.101-1.500 inch54 mils48 mils
BraidOptional
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024