APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10733 Issued:2003-09-26
Revised:2019-11-07
Style 10733 Multiple-conductor cable using non-integral jacket.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG min., solid or stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyOne individually insulated conductor to form a round or flat cable. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the individual conductor.
ShieldOptional.
JacketTPE
major dia in inches
0.350 or less15 mils min average12 mils minimum at any point
0.351-0.700 dia30 avg24 min
0.701-1.000 dia40 avg36 min
1.101-1.500 dia54 avg48 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.