Rating | 105 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 36 AWG min., solid or stranded. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | One individually insulated conductor to form a round or flat cable. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the individual conductor. |
|
Shield | Optional. |
|
Jacket | TPE |
| major dia in inches |
| 0.350 or less | 15 mils min average | 12 mils minimum at any point |
| 0.351-0.700 dia | 30 avg | 24 min |
| 0.701-1.000 dia | 40 avg | 36 min |
| 1.101-1.500 dia | 54 avg | 48 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|