APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10734 Issued:2003-09-26
Revised:2011-08-01
Style 10734 Single Conductor with Extruded Insulation and Jacket

Rating105 deg C, 600 Vac, Horizontal flame.
Conductor36 AWG minimum, solid or stranded
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyFillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the individual conductor.
ShieldOptional
JacketExtruded TPE
Diameter Under Jacket - Major Diameter if Flat (inch)Minimum average thickness (mils)Minimum thickness at any point (mils)
0.350 or less1512
0.351-0.7003024
0.701-1.0004036
1.101-1.5005448
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseInternal wiring

UL and the UL Logo are trademarks of UL LLC © 2024