Rating | 150 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 50 AWG - 12 AWG, stranded flat or round, multiple stranded conductors may be laid parallel to form a flat construction. |
|
Insulation | Extruded ETFE |
| Conductor size | Minimum average thickness | Minimum thickness at any point |
| 50-14 AWG | 9 mils | 8.1 mils |
| 13-1 AWG | 15 mils | 13.5 mils |
|
Assembly | Multiple stranded conductors may be laid parallel to form a flat construction. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|