APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10749 Issued:2003-11-13
Revised:2011-10-26
Style 10749 Single-conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Cable flame.
Conductor40 AWG min.
InsulationLabeled or complying with manufacturer's ConductorAWM Procedure.
ShieldOptional.
CoveringOptional. Extruded PVC, 6 mil minimum thickness or heavier.
JacketExtruded PVC.; dia in inches of 0.425 or less, 30 mils minimum average thickness, 24 mils minimum thickness at any point; 0.426 - 0.700 dia, 45 avg, 36 min; 0.701 - 1.000 dia, 60 avg, 48 min; 1.001 - 1.500 dia, 80 avg, 64 min; 1.501 - 2.500 dia, 110 avg, 88 min; 2.501 dia and larger, 140 avg, 112 min.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024