APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10755 Issued:2003-11-13
Revised:2011-09-16
Style 10755 Single conductor with extruded insulation and Jacket

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 16 AWG solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
CoveringOptional. Extruded PVC 6 mil or heavier.
ShieldOptional.
JacketExtruded PVC
diameter of core assembly under jacketminimum average thicknessminimum thickness at any point
0.350 inch or less18 mils16 mils
0.351-0.700 inch30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024