APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10763 Issued:2003-11-13
Revised:2019-11-07
Style 10763 Jacketed Wire.

Rating80 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
ShieldOptional.
CoveringOptional. Extruded PVC 6 mil or heavier.
JacketFRPE
dia in inches
0.700 or less30 mils min average24 mils minimum at any point
701-1.000 dia45 avg36 min
1.001-1.50 dia60 avg48 min
1.501-2.500 dia80 avg64 min
2.501-4.000 dia110 avg88 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024