APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10774 Issued:2003-11-13
Revised:2011-09-20
Style 10774 Single Conductor Cable with Non-Integral Jacket

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor36 AWG minimum.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
CoveringOptional.
ShieldOptional.
JacketExtruded TPU
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
2.501-4.000 inch110 mils88 mils
4.001 and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024