APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1078 Issued:1959-05-01
Revised:2012-03-06
Style 1078 Single or multiple conductor with extruded insulation

Rating90 deg C, 300 Vac, Horizontal flame.
ConductorMinimum 0.0025 inch diameter resistance wire wound for a minimum 20 turns per inch on a Rayon, Cotton, Polyester or Fiberglass yarn core.
InsulationExtruded PVC 30 mils minimum average thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring where not subjected to flexing or motion.