| Rating | 105 deg C, 125 Vac, Horizontal flame. |
|
| Conductor | 39 - 31 AWG Resistance Wire. Copper, nickel-alloy, or stainless steel. Sensor Wire - 40-35 AWG, same material as the conductor wrapped over sensor layer. |
|
| Assembly | Conductor wound 10 turns per inch min 70 turns per max. On a core of Acrylic, Fiberglass, Polyester or Rayon. Core may be coated with Silicone Rubber. Sensor Wire - wound 10 turns per inch min 70 turns per max. A conductor core with sensor layer, sensor wire and insulation. |
|
| Sensor Layer | Extruded PVC. 14 mils minimum average thickness, 12 mils minimum thickness at any point. |
|
| Insulation | Extruded PVC. 17 mils minimum average thickness, 15 mils minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | High Resistance Heater Wire. |
|