APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10816 Issued:2004-01-16
Revised:2011-10-11
Style 10816 Single conductor with extruded insulation.

Rating250 deg C, 150 Vac, Horizontal flame.
Conductor40 AWG - 10 AWG solid or stranded.
InsulationExtruded PFA
40-20 AWG conductor size6 mils min average5 mils minimum at any point
19 AWG9 avg8 min
18-10 AWG12 avg11 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances and Electronic Equipment.