| Rating | 250 deg C, 300 Vac, Horizontal flame. |
|
| Conductor | 40 AWG - 4/0 AWG solid or stranded round. |
|
| Insulation | Extruded PFA |
| Conductor size | Minimum average thickness | Minimum thicknes at any point |
| 40-19 AWG | 9 mils | 8 mils |
| 18-4/0 AWG | 15 mils | 13 mils |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal Wiring of Appliances and Electronic Equipment. |
|