Rating | 105 deg C, 150 Vac, Horizontal flame. |
|
Conductor | Heater conductor - 40 - 34 AWG solid conductor spirally wound over a fiber core. (60 - 15) turns per inch). Sensor Layer - PE, 14 mils minimum average thickness, 12 mils minimum thickness at any point. Not Evaluated as a Sensor Layer. Sensor wire - 41-34 AWG solid. |
|
Sensor Layer | Extruded PE, 14 mils min average, 12 mils minimum at any point. Not Evaluated as a Sensor Layer. |
|
Assembly | A conductor spirally wound over a fiber core(60 - 15) turns per inch, then with a sensor layer and sensor wire spirally wound over at (70 - 10) turns per inch, then outer insulation. |
|
Insulation | Extruded PVC, 20 mils min average, 18 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. High Resistance Heater Wire. |
|