APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10839 Issued:2004-03-01
Revised:2019-11-07
Style 10839 Jacketed Cable.

Rating60 deg C, 90 Vac, Cable flame.
InsulationLabeled or complies with manufacturer's AWM Procedure.
ShieldOptional.
CoveringOptional.
JacketTPU
dia. in inches
0.400 or less24 mils min average20 mils minimum at any point
0.401-0.700 dia30 avg24 min
0.701-1.500 dia45 avg36 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024