APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10845 Issued:2004-03-01
Revised:2011-09-14
Style 10845 Single-conductor cable using non-integral jacket.

Rating80 deg C, 150 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
CoveringOptional.
ShieldOptional.
JacketExtruded TPU
@ Diameter of cable under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
@ Equivalent diameter of flat assembly = 1.1284 x (TW)^0.5 where T is the thickness of the assembly under jacket and W is the width of the assembly under jacket
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024