APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10846 Issued:2004-03-01
Revised:2011-09-14
Style 10846 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
CoveringOptional.
ShieldOptional.
JacketExtruded TPU
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external interconnection of electronic equipment.