Subj.758 Section 1 Page 10858 Issued:2004-03-01
Revised:2011-08-04
Style 10858 Single Conductor with Extruded Insulation and Jacket

Rating80 deg C, 1000 Vac, Horizontal flame
InsulationLabeled or complies with manufacturer's AWM Procedure.
ShieldOptional
CoveringOptional
JacketExtruded PUR, 15 mils minimum average thickness, 12 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseInternal wiring electronic equipment