APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10883 Issued:2004-04-27
Revised:2019-11-07
Style 10883 Single conductor cable using non-integral jacket

Rating75 deg C, 30 Vac, Cable flame.
Conductor30 AWG - 4/0 AWG solid or stranded.
InsulationLabeled or complying with Manufacture's AWM Procedure.
AssemblySingle conductor Fillers and/or barrier layers optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional. A 6 mil, or heavier, FRPE covering may be extruded over conductor assembly.
ShieldOptional.
JacketExtruded FRPE
dia in inches
0.700 or less30 mils min average24 mils min at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
2.501 dia and large90 avg72 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances and external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024