APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10920 Issued:2004-10-21
Revised:2011-08-04
Style 10920 Single Conductor with Extruded Insulation

Rating80 deg C, 150 Vac, Horizontal flame
Inner Conductor40 AWG - 31 AWG, spirally wound over a fiber core, 70 - 10 turns per inch
Inner InsulationExtruded PE, 14 mils minimum average thickness, 12 mils minimum thickness at any point
Outer Conductor44 AWG - 31 AWG, spirally wound over a fiber core, 70 - 10 turns per inch
Outer InsulationExtruded PVC, 20mils minimum average thickness, 18 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseInternal wiring of Electric Appliances

UL and the UL Logo are trademarks of UL LLC © 2024