APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10935 Issued:2005-01-25
Revised:2011-11-01
Style 10935 Single conductor with extruded insulation.

Rating150 deg C, 600 Vac, Horizontal flame.
Conductor24 AWG - 4/0 AWG, solid or stranded.
InsulationExtruded ETFE
Conductor sizeMinimum average thicknessMinimum thickness at any point
24-186.0 mils5.0 mils
16-148.0 mils7.0 mils
12-1010.0 mils9.0 mils
9-220.0 mils18.0 mils
1-4/030.0 mils27.0 mils
CoveringLacquered Polyester Braid
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.