APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10947 Issued:2005-02-02
Revised:2019-11-07
Style 10947 Single-conductor cable using non-integral jacket

Rating105 deg C, 600 Vac, Cable flame.
ConductorSolid or stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure with minimum rating of 105 deg C, 600 V.
CoveringOptional.
ShieldOptional.
JacketExtruded XLPE
dia of Cable Under Jacket in inches
0.700 or less30 mils min average24 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024