APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10950 Issued:2005-02-02
Revised:2012-04-18
Style 10950 Single condcutor with non-integral jacket

Rating125 deg C, 600 Vac, Cable flame.
Insulated singlesLabeled or complying with manufacturer's AWM Procedure with minimum rating of 125C, 600V.
CoveringOptional.
ShieldOptional.
JacketXLPE
Dia. of round assembly under jacket (inch)Minimum average thicknessMinimum thickness at any point
0.700 or less3024
0.701 - 1.0004536
1.001 - 1.5006048
1.501 - 2.5008064
# Equivalent diameter of flat assembly = 1.1284 x (TW)0.5, where T is the thickness of the assembly under jacket, and W is the width of the assembly under jacket.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024