APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11015 Issued:2006-02-24
Revised:2011-08-12
Style 11015 Single conductor cable using extruded non-integral jacket

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG - 10 AWG solid or stranded.
InsulationExtruded SRPVC, 6 mils minimum average thickness, 5 mils minimum thickness at any point.
ShieldOptional. Spiral wrapped strands.
JacketExtruded PVC, 12 mils minimum average thickness, 10 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.