APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11016 Issued:2006-03-01
Revised:2011-09-14
Style 11016 Single Conductor with Extruded Insulation

Rating105 deg C, 150 Vac, Horizontal flame.
ConductorHeater Conductor - Flat Wire, 41 AWG - 33 AWG, 0.7 mils x 10 mils minimum to 2.0 mils x 21 mils, solid conductor spirally wound over a fiber core. (60 - 15) turns per inch).
Sensor LayerPVC, 14 mils minimum average thickness, 12 mils minimum thickness at any point. Not evaluated as a sensor layer.
ConductorSensor Conductor - 41 AWG - 34 AWG solid conductor spirally wound over the inner insulation. (70 - 10 turns per inch).
InsulationPVC, 20 mils min average, 18 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring. High Resistance Heater Wire.

UL and the UL Logo are trademarks of UL LLC © 2024