APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11019 Issued:2006-03-17
Revised:2012-04-20
Style 11019 Insulated wire.

Rating105 deg C, 150 Vac, Horizontal flame.
ConductorSensor Conductor - 24 AWG, wraps around tinsel wire fiber core, 4 conductor strands, 10.0 mil strand diameter, 0.5 inches lay of strands.
Sensor LayerPVC or PE, 12 mils minimum average thickness, 10 mils minimum thickness at any point, 18 mils core diameterNot evaluated as a Sensor Layer.
ConductorHeater Conductor - Flat Wire, 41 AWG - 33 AWG, (0.7 mils x 10 mils minimum to 2 mils x 21 mils), wraps around inner insulating covering, 40-15 turns per inch.
InsulationPVC, 20 mils min average, 18 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring, High Resistance Heater Wire.

UL and the UL Logo are trademarks of UL LLC © 2024