APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11039 Issued:2006-07-08
Revised:2011-09-22
Style 11039 Triaxial cable

Rating105 deg C, 150 Vac, Horizontal flame.
Conductor40 AWG - 31 AWG Conductor spirally wound over a fiber core, 10-70 turns per inch;
InsulationInner Insulation - Nylon (Polyamid), 6 mils minimum average, 5 mils minimum at any point.
Conductor44 AWG - 31 AWG Conductor spirally wound over Inner Insulation, 10-70 turns per inch;
InsulationMiddle Insulation - Nylon (Polyamid), 6 mils minimum average, 5 mils minimum at any point.
Conductor40-31 AWG conductor spirally wound over Middle Insulation, 5-70 turns per inch.
InsulationOuter Insulation - PVC, 18 mils minimum average, 16 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2025