APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11042 Issued:2006-08-18
Revised:2011-10-17
Style 11042 Single-conductor cable using non-integral jacket

Rating105 deg C, 30 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure having minimum rating of 105 deg C, 30 Vac.
CoveringOptional.
ShieldOptional.
JacketmPPE.
dia of assembly under jacket*Minimum averageMinimum at any point
0.700 inch or less9 mils7 mils
0.701-1.500 inch10 mils8 mils
*Equivalent diameter of flat assembly = 1.1284 x (TW)0.5 where T is the thickness of the assembly under jacket, and W is the width of the assembly under jacket.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external wiring in Class 2 circuits.

UL and the UL Logo are trademarks of UL LLC © 2024