APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1108 Issued:1959-05-01
Revised:2014-02-25
Style 1108 Single conductor with extruded insulation using non-intergral jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG, solid or stranded.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point, or Extruded FEP or PTFE, 13 mils minimum average thickness, 12 mils minimum thickness at any point, or Labeled or Complies with manufacturer's Procedure.
CoveringOptional- Lacquered glass, rayon cotton.
ShieldOptional.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024