APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11083 Issued:2006-12-01
Revised:2011-10-04
Style 11083 Single conductor with extruded insulation and jacket.

Rating125 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG - 10 AWG.
InsulationExtruded PFA, 1 mils minimum thickness at any point.
ShieldRequired.
CoveringOptional inner layer.
JacketExtruded PFA, 1 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.