APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11101 Issued:2007-06-01
Revised:2012-04-26
Style 11101 Single Conductor with Extruded Insulation.

Rating90 deg C, 600 Vac, Horizontal flame.
Conductor32 AWG - 10 AWG min. solid or stranded round, tinned or bare copper.
InsulationExtruded PE, 25 mils min average, 23 mils minimum at any point. See facing page for compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or for further processing.