APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11129 Issued:2007-11-16
Revised:2011-12-06
Style 11129 Single-conductor cable using non-integral jacket

Rating200 deg C, 20000 Vdc, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
JacketExtruded SR, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.