APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1115 Issued:1959-05-01
Revised:2012-10-17
Style 1115 Single conductor cable using non-integral jacket

Rating80 deg C, 300 Vac (Insulation), 600 Vac (Jacket), Horizontal flame.
Conductor30 AWG - 16 AWG, solid or stranded, tinned or bare copper.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded PVC, 30 mils minimum average thickness, 23 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph pick-up and volume control; or as internal wiring of appliances. Tags may also indicate that the insulation is suitable for 600 volts peak - for electronic use.

UL and the UL Logo are trademarks of UL LLC © 2024