Subj.758 Section 1 Page 1116 Issued:1959-05-01
Revised:2014-03-14
Style 1116 Single Conductor Cable using Extruded Non-Integral Jacket

Rating80 deg C, 600 Vac, Horizontal flame.
Conductor30 AWG - 12 AWG, solid or stranded.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances, or electronic equipment. Tags may indicate the following: "2500 Volt Peak for Electronic Use Only".