APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11164 Issued:2008-09-10
Revised:2011-10-20
Style 11164 Single conductor cable using non-integral jacket.

Rating80 degC, 30 V, Horizontal flame.
Conductor32 AWG - 12 AWG, solid or stranded.
InsulationTPE, 7 mils minimum average, 6 mils minimum at any point.
ShieldOptional.
CoveringOptional.
JacketTPE, 13 mils minimum average, 10 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024