APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11166 Issued:2008-09-10
Revised:2011-08-04
Style 11166 Single Conductor with Extruded Insulation and Jacket

Rating80 deg C, 300 V, Horizontal flame
Conductor32 AWG - 12 AWG, solid or stranded.
InsulationExtruded TPE, 7 mils minimum average thickness, 6 mils minimum thickness at any point
ShieldOptional
CoveringOptional
JacketExtruded TPE, 13 mils minimum average thickness, 10 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseInternal wiring

UL and the UL Logo are trademarks of UL LLC © 2024