Rating | 90 deg C, 300 Vac (Insulation), 600 Vac (Jacket), Horizontal flame. |
|
Conductor | 26 AWG - 16 AWG, solid or stranded. |
|
Insulation | Extruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
Covering | Lacquered braid. |
|
Shield | Optional. |
|
Jacket | Extruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Phonograph Pick-Up and Volume Control; or as Internal Wiring of Appliances. Tags may also indicate that the insulation is suitable for 600 Volts peak - for electronic use. |
|