APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1119 Issued:1959-05-01
Revised:2014-05-20
Style 1119 Single-conductor cable using non-integral jacket

Rating90 deg C, 600 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG, solid or stranded.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
Shield36-30 AWG. tinned or untinned copper strands applied as a wrap or braid.
JacketExruded PVC, 30 mils min average, 24 mils minimum at any point, or lacquered braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-Up and Volume Control; or In the Internal Wiring of Appliances.