APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1120 Issued:1959-05-01
Revised:2013-11-22
Style 1120 Single conductor with extruded insulation and extruded jacket

Rating105 deg C, 600 Vac, Horizontal flame.
Conductor30 AWG - 4/0 AWG, solid or stranded.
InsulationExtruded PVC.
Conductor sizeMinimum average thicknesMinimum thickness at any point
30-10 AWG30 mils27 mils
9-8 AWG, 45 mils, 40 mils; #7-2 AWG, 60 mils, 54 mils; #1-4/0 AWG, 80 mils, 72 mils
ShieldOptional.
Inner JacketExtruded PVC.
Conductor sizeMinimum average thicknessMinimum thickness at any point
30-2 AWG30 mils24 mils
1-4/0 AWG45 mils36 mils
ShieldOptional.
Outer JacketOptional - Extruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances or phonograph pick-up and volume control.