APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11206 Issued:2009-07-09
Revised:2011-10-13
Style 11206 Single conductor with extruded insulation

Rating90 deg C, 125 Vac, Horizontal flame.
Conductor39-31 AWG.
InsulationExtruded PVC, 18 mils minimum average thickness, 16 mils minimum thickness at any point.
CoveringExtruded PVC, extruded PE or extruded Nylon, provided over Conductor.
Misc.Sensor Wire - 40-35 AWG, copper, nickel-alloy, or stainless steel, wound around Covering.
AssemblyConductor wound around a core of Acrylic, Fiberglass, Polyester or Rayon, with 10 turns per inch minimum and 70 turns per inch maximum, core may be coated with Silicone Rubber. Conductor covered by Covering. Sensor Wire wound around Covering, with 10 turns per inch minimum and 70 turns per inch maximum, covered by Insulation.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024