APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11220 Issued:2009-06-05
Revised:2012-05-25
Style 11220 Signle conductor using non-integral jacket.

Rating105 deg C, 600 Vac, Cable flame.
Conductor50 AWG - 10 AWG. Solid or stranded round.
InsulationLabeled or complying with manufacturer's AWM procedure.
ShieldBraid.
JacketExtruded PVC.
Diameter of core assembly under jacketMinimum avergage thicknessMinimum thickness at any point
0.700 or less30 mils24 mils
0.701-1.00045 mils36 mils
1.001-1.50060 mils48 mils
1.501-2.50080 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnect of appliances.

UL and the UL Logo are trademarks of UL LLC © 2024