APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11227 Issued:2009-08-27
Revised:2011-10-12
Style 11227 Single-conductor cable using non-integral jacket

Rating200 deg C, 30 Vac, Horizontal flame.
Conductor44 AWG - 10 AWG, solid or stranded.
InsulationExtruded MFA, 3 mils minimum average, 2 mils minimum at any point.
ShieldOptional.
JacketExtruded FEP, 3 mils minimum average, 2 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.