APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 11229 Issued:2009-09-04
Revised:2011-10-26
Style 11229 Single-conductor cable using non-integral jacket.

Rating150 deg C, 150 Vac, Horizontal flame. Optional: 60 deg C Oil, 80 deg C Oil or Gasoline Resisitance.
Conductor50 AWG - 10 AWG, solid or stranded.
InsulationExtruded FEP, 20 mils minimum average thickness, 18 mils minimum thickness at any point.
JacketOptional, Extruded FEP, 8 mils minimum average thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.